strongRequirements for equipment installationstrong
The sensors communicate using zigbee protocol
Tuya Zigbee Hub GateWay is required to work together must
Other Zigbee Hubs are not supported Zigbee2MQTT is not supported
strongAbout Update Frequencystrong
1 The sensor uses a trigger mechanism When the temperature or humidity changes to the set value the sensor will report the data immediately Generally the data is updated once an hour
2 The sensor cannot set the update report data frequency
3 The sensor cannot set alarm The alarm function is set on the APP
If you need to update data in real time please purchase a USB powered versionTH06TH16
strongAbout Proper Selection and Use of Batteriesstrong
1 Only LR0315V alkaline battery can be used 12V rechargeable battery may cause the equipment to detect wrong voltage and report low voltage
2 Batteries of different models or brands cannot be mixed
4 New and old batteries cannot be mixed
5 It is prohibited to use inferior batteries
Otherwise 1 Configuration fails 2 Battery consumption is too fast
How to obtain highquality battery Please buy in a regular supermarket or chain supermarket
Note After the device configuration is completed it needs to be placed in a position where the wireless signal is good otherwise the device signal power will become larger which will lead to excessive battery consumption
strongAbout Network Testingstrong
Devices using the network consume a lot of power To ensure the service life of the battery the device will stop using the network when it does not need to report data
Therefore it is meaningless to test the network signal of sensors in APP
strongError on temperature and humiditystrong
1 All temperature and humidity sensors will have certain errors please note The temperature error of this sensor is 1 and the humidity error is 5 RH Any value within this range is normal
2 The sensor error and manufacturing process will meet and there will also be some errors between products of the same model
3 According to Newtons third law heat conduction takes a certain time The sensor needs 30 minutes or 1 hour to be consistent with the room temperature and the measurement will be accurate
strongHistorical curve of temperature and humiditystrong
1 The minimum granularity of historical data daily chart is 1 hour and the minimum granularity of exported data is also 1 hour
2 Days of historical data are stored for 7 days
3 The value of historical data is the average value That is the average value of a minimum granularity time
strongSupport for thirdparty smart speakersstrong
1 Because the thirdparty smart speakers Google HomeAmazon Alexa do not have control panels corresponding to temperature and humidity sensors
Therefore the APP of thirdparty smart speakers may not display the temperature and humidity correctly
But we have developed voice query function Therefore the current temperature and humidity can be queried by voice
2 Route or automatic process related to temperature and humidity cannot be established on the thirdparty smart speakers
3 The device does not support Yandex Alice
strongTrigger mechanism of temperature and humidity in automatic processstrong
We used Edge Triggered ET
That is the action can only be triggered if the condition crosses the set condition
A For example turn on the light when the automatic setting temperature is greater than 25
A1 When the temperature rises from below 25 to 25 the automatic process can trigger the ON light
A2 After the automatic process is set the temperature is always above 25 and the lamp is not turned on
B For example when the automatic setting temperature is less than 20 turn on the light
B1 When the temperature drops from above 20 to 20 the automatic process can trigger the start lamp
B2 After the automatic process is set the temperature is always below 20 and the lamp is not turned on
strongWhen will the battery consume quicklystrong
1 The correct type of battery is not selected or the battery is mixed
2 The sensor shall be installed at the location where the ambient temperature or humidity changes dramatically In this environment the device will frequently start the network to report data
3 The sensor is installed in a low temperature environment for a long time such as less than 0 and the battery performance will decline rapidly at this temperature
4 The sensor is installed at a location where the network signal is very poor When the network signal is poor the equipment will increase the transmission power of the signal resulting in increased power consumption
5 The equipment is in a high humidity environment for a long time which will corrode the battery and cause battery leakage
Weight | 1 kg |
---|