strongProduct Featuresstrong
High precision
Powerful features
Easy to use
Easy to operate
Wide application range
strongProduct parametersstrong
DTC1201 2201 temperature controller
Product name Temperature controller
Product model DTC1201 2201
Power supply voltage AC110230V
Temperature range 40 99
Temperature measurement accuracy 1 40 70
Sensor wire length 100cm
Temperature controller size 93mm 56mm 34mm
Output capacity Refrigeration 10A250VAC Heating 10A250VAC
strongParameter setting methodstrong
When the temperature controller works normally press and hold the key for more than 3 seconds to enter the parameter modification mode The Set indicator lights up and the Nixie tube displays the code F1 of the first menu item Press the or key to increase or decrease the code of the menu item and press the key to display the parameter setting value of the current menu Press and hold the key and then press the or key briefly to increase or decrease the code and display the parameter setting value of the current menu Hold down the key while holding down the or key for a long time to quickly adjust up or down and display the parameter settings of the current menu
Press and hold the and keys at the same time then power on and the parameters Factory reset
strongOperating instructionsstrong
When the thermostat is working normally holding down the power button for more than 3 seconds will turn off the thermostat When the thermostat is turned off holding down the power button for more than 3 seconds will turn on the thermostat
When the temperature controller works normally the Nixie tube displays the current temperature measurement value and automatically recognizes and converts the cooling and heating working mode
When the measured temperature is the temperature set valuethe temperature difference set value it enters the cooling state the Cool indicator light is on and the normally open contact of the cooling relay is closed The Cool indicator light flashes indicating that the refrigeration equipment is in the delayed protection state of the compressor When the measured temperature is the set temperature value the Cool indicator light goes out and the normally open contact of the refrigeration relay opens
When the measured temperature is the temperature set value temperature difference set value it enters the heating state the Heat indicator light is on and the normally open contact of the heating relay is closed When the measured temperature is the set temperature value the Heat indicator light goes out and the normally open contact of the heating relay opens
Indicator light status description
Notes on indicator light function
Cool indicator light is on refrigeration is working Off Cooling off Flashing The compressor delay Cool and Heat indicator lights cannot light up simultaneously
Heat indicator light is on heating is working Off Heating off
Set indicator light on parameter setting status
Data indicator light blue light yellow light Data transmission indicator light Yellow light Distribution network indicator light
Net indicator light on online flashing offline indicating whether the APP and device are successfully connected
strongMenu Function Descriptionstrong
Menu Identification Menu Function Setting Range Factory Settings
F1 temperature setting value 400999 100
F2 temperature difference setting value 03100 1
F3 press with a delay of 110 minutes and 3 minutes
F4 temperature correction 100100 0
nbsp
1 Temperature setting ambient temperature required by the user Users can adjust it on the temperature controller or APP with an adjustment range of 40 to 999 degrees Celsius
2 Temperature difference setting Set the difference between the target temperature for heating or cooling when operating at a constant temperature For example if the target temperature is 40 degrees the temperature difference is set to 2 degrees After heating to 40 degrees stop heating and enter the constant temperature mode When the temperature drops to 38 degrees enter the heating mode again The difference in this value is 2 degrees This value can be adjusted through the host or APP with an adjustment range of 0 to 10 degrees Celsius
3 Compressor delay This function is generally used for compressor cooling If the temperature controller is used for refrigerators and freezers this value must be set According to the return pressure of the compressor the general setting value is 36 minutes which can be adjusted through the host or APP with an adjustment range of 0 to 10 minutes
4 Temperature correction used to correct the temperature value currently detected by the temperature controller with a correction range of 0 to 10 degrees Celsius
strongDistribution Network Descriptionstrong
1 Please download the Graffiti Intelligence app from the app store and register to log in
2 Click on Add Device
3 Power on the device first power off after 10 seconds and then power on
4 Press and hold simultaneously and after 5 seconds the distribution indicator light will flash once in 2 seconds then press the mobile app to confirm the distribution
5 Wait for successful distribution network
strongWiring instructionsstrong
Fix system data
After the temperature controller is powered on first check if the parameter settings are correct If an error is detected it will display Er At this time pressing any key will restore the default parameter settings and work normally It is recommended to reset the parameters at this time
System code cause and action
Sensor fault alarm when the temperature probe circuit has short circuit or open circuit faults the temperature controller starts the probe fault alarm mode closes all execution states and the Nixie tube displays EE After the fault is removed press any key to return to the normal working mode
Over temperature limit alarm when the temperature measurement exceeds the temperature measurement range the temperature controller starts the over temperature limit fault alarm mode closes all execution states and the Nixie tube displays HH When the temperature returns to the normal measurement range press any key to return to the normal working mode 18b20
strongSafety rulesstrong
Danger
1 Strictly distinguish between sensor leads power lines and output relay interfaces and do not connect them incorrectly Relays should not be overloaded
2 All wiring changes must be made with the power disconnected
Warning
1 This temperature controller is prohibited from use in water or excessively humid environments as well as in high temperatures strong electromagnetic interference and corrosive environments
Attention
1 The power supply voltage should be consistent with the voltage marked on the temperature controller and ensure the stability of the power supply voltage
2 To avoid possible interference it is recommended to maintain an appropriate distance between the sensor lead and the power line
strongPackage Liststrong
1X controller
1X antenna